Comfortable, Ergonomic Design: Ensures operator comfort and productivity with a gun-shaped form factor optimized for intensive hand-held scanning. Class-Leading Durability: Increases up time and reduces service costs with a reliable design that utilizes no moving parts and full impact resistant bumpers. Dimensions Overall Dimensions 15 x Service Terms Warranty Duration 5 yr.
Others Power Connector Type Corded. Features Form Factor Gun Shape. Features Automatic Interface Detection. Scanning Specifications Decode Capability 1D. Depth of Field 0. Pitch Skew Brightness 0 - lux. Even better, it eliminates the need to buy specialty scanners. And with no moving parts to wear out, the Hyperion g scanner is one of the toughest general duty scanners on the market — so tough, in fact, you can hammer nails with it! Administrator rights are required to install the device driver.
If you do not have administrative rights to the computer s you are installing the device, contact Central Office support or your IT department. If you do not already have a Honeywell account, you will need to create one. Click Install to begin the installation process. Administrative rights to the computer are necessary to install the driver. You may need to contact your IT department to install the driver or allow you administrative rights to the computer.
Download and install the Honeywell Download Manager. The Honeywell Driver Wizard may now be used to install the printer, itself. Technical Support - PPR. Search Community and Knowledge Base. Sign in to ask the community. Home Technical Support Why should I register?
Bar Code Scanners. System Article Number. Last Modified Date. How may I download the latest Intermec and Honeywell print drivers: directly from Honeywell?
From where may I download a legacy non-current version of the Intermec InterDriver? The scanner beeps once. A carriage return CR suffix is added to bar code data. Connect the appropriate interface cable to the scanner.
Plug the serial connector into the serial port on your computer. Tighten the two screws to secure the connector to the port. Once the scanner has been completely connected, power up the computer. This interface programs 38, baud, 8 data bits, no parity, and 1 stop bit.
For further RS settings, refer to RS on page The scanner has a bright red aiming beam that corresponds to its horizontal field of view. The aiming beam should be centered horizontally over the bar code; it will not read if the aiming beam is in any other direction. The best focus point for reading most code densities is about 5 inches To read a single bar code or multiple bar codes on a page or on an object , hold the scanner at an appropriate distance from the target, pull the trigger, and center the aiming beam on the bar code.
Honeywell scanners are programmed by scanning menu bar codes or by sending serial commands to the scanner. If you want to restrict the ability to scan menu codes, you can use the Menu Bar Code Security settings. Contact Technical Support see Customer Support on page for further information. You have the ability to create a set of menu commands as your own, custom defaults. To do so, scan the Set Custom Defaults bar code below before each menu command or sequence you want saved.
If your command requires scanning numeric codes from the back cover, then a Save code, that entire sequence will be saved to your custom defaults.
Scan the Set Custom Defaults code again before the next command you want saved to your custom defaults. You may have a series of custom settings and want to correct a single setting. To do so, just scan the new setting to overwrite the old one. For example, if you had previously saved the setting for Beeper Volume at Low to your custom defaults, and decide you want the beeper volume set to High, just scan the Set Custom Defaults bar code, then scan the Beeper Volume High menu code.
The rest of the custom defaults will remain, but the beeper volume setting will be updated. If you want the custom default settings restored to your scanner, scan the Activate Custom Defaults bar code below. This resets the scanner to the custom default settings.
If there are no custom defaults, it will reset the scanner to the factory default settings. Any settings that have not been specified through the custom defaults will be defaulted to the factory default settings. Plug and Play bar codes provide instant scanner set up for commonly used interfaces. Note: After you scan one of the codes, power cycle the host terminal to have the interface in effect. Keyboard wedge is the default interface.
For most laptops, scanning the Laptop Direct Connect bar code allows operation of the scanner in parallel with the integral keyboard. The following RS Interface bar code also programs a carriage return CR and a line feed LF suffix, baud rate, and data format as indi-.
Note: After scanning one of these codes, you must power cycle the cash register. Scanning these codes also adds a CR and LF. The driver will use the next available COM Port number. Scan the following Plug and Play code to program the scanner for a Honeywell bioptic scanner auxiliary port configuration.
This bar code sets the baud rate to bps and the data format to 8 data bits, no parity, 1 stop bit. Note: If you are having unexpected results with this programming code, scan the Resetting the Custom Defaults bar code on page first, then scan the programming code above. Scan the following Plug and Play code to program the scanner for a Datalogic Magellan bioptic scanner auxiliary port configuration. This bar code sets the baud rate to bps and the data format to 8 data bits, odd parity, 1 stop bit.
Scan the appropriate country code below to program the keyboard layout for your country or language. As a general rule, the following characters are supported, but need special care for countries other than the United States:. If your keystrokes require the ALT key and 4 characters, scan the 4 Characters bar code. The data is then output with the special character s.
This programs keyboard styles, such as Caps Lock and Shift Lock. Regular is used when you normally have the Caps Lock key off.
Caps Lock is used when you normally have the Caps Lock key on. Shift Lock is used when you normally have the Shift Lock key on not common to U. Automatic Caps Lock is used if you change the Caps Lock key on and off. Autocaps via NumLock bar code should be scanned in countries e. Note: After scanning the Emulate External Keyboard bar code, you must power cycle your computer. Windows is the preferred mode. All keyboard country codes are supported.
DOS mode is a legacy. New users should use the Windows mode. Numeric Keypad Mode: Sends numeric characters as if entered from a numeric keypad. Baud Rate sends the data from the scanner to the terminal at the specified rate.
The host terminal must be set for the same baud rate as the scanner. Data Bits sets the word length at 7 or 8 bits of data per character. Stop Bits sets the stop bits at 1 or 2. Parity provides a means of checking character bit patterns for validity. Note: When using 7 Data, 1 Stop, Parity None, the host must insert at least a 1 bit delay between characters.
If this is not done, a different RS Word. RS Handshaking allows control of data transmission from the scanner using software commands from the host device. If the delay time expires and CTS is not asserted, the device transmit buffer is cleared and scanning may resume.
When CTS is not asserted, scanning is disabled. CTS is ignored. When using Flow Control with Timeout, you must program the length of the delay you want to wait for CTS from the host. Set the length in milliseconds for a timeout by scanning the bar code below, then setting the timeout from 1- milliseconds by scanning digits from the inside back cover, then scanning Save.
Data transmission continues where it left off when XOFF was sent. After transmitting data, the scanner waits for an ACK character hex 06 or a NAK character hex 15 response from the host. If ACK is received, the communications cycle is completed and the scanner looks for more bar codes.